Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
China Pharmacy ; (12): 2981-2984, 2017.
Article in Chinese | WPRIM | ID: wpr-617679

ABSTRACT

OBJECTIVE:To develop a method for simultaneous determination of chlorogenic acid,baicalin,aloe emodin,rhe-in,emodin,chrysophanol and physcione in Kangjun xiaoyan tablets. METHODS:RP-HPLC method was adopted. The determina-tion was performed on Agilent Extend C18 with mobile phase consisted of acetonitrile-0.5% phosohoric acid solution(gradient elu-tion)at the flow rate of 1.0 mL/min. The detection wavelengths were set at 327 nm(chlorogenic acid),280 nm(baicalin)and 450 nm(aloe emodin,rhein,emodin,chrysophanol,physcione). The column temperature was 30℃,and sample size was 10μL. RE-SULTS:The linear ranges of chlorogenic acid,baicalin,aloe emodin,rhein,emodin,chrysophanol and physcione were 0.2094-4.1880μg(r=0.9999),0.3720-7.4400 μg(r=0.9999),0.0063-0.1262 μg(r=0.9999),0.0116-0.2322 μg(r=0.9999),0.0053-0.1060 μg(r=0.9998),0.0128-0.2564 μg(r=0.9999),0.0165-0.3303 μg(r=0.9998),respectively. The limits of quantita-tion were 2.01,1.93,0.76,1.25,1.24,0.53 and 1.53 ng;the limits of detection were 0.98,0.65,0.25,0.42,0.41,0.18 and 0.52 ng,respectively. The recoveries were 98.41%-100.40%(RSD=0.76%,n=9),96.17%-100.10%(RSD=1.58%,n=9), 96.11%-100.10%(RSD=1.33%,n=9),96.29%-100.80%(RSD=1.85%,n=9),96.88%-100.10%(RSD=1.22%,n=9), 97.81%-101.90%(RSD=1.64%,n=9),96.46%-101.30%(RSD=1.85%,n=9),respectively. CONCLUSIONS:The method is accurate,reliable and reproducible. It can be used for simultaneous determination of 7 components in Kangjun xiaoyan tablets.

2.
China Pharmacy ; (12): 833-834,835, 2016.
Article in Chinese | WPRIM | ID: wpr-605264

ABSTRACT

OBJECTIVE:To establish a method for the simultaneous determination of chlorogenic acid and vitexin in Lophather-um gracile. METHODS:HPLC was performed on the column was Waters Atlantis C18 with mobile phases of acetonitrile- water (gradient elution)at a flow rate of 1.0 ml/min,detection wavelength was 280 nm,column temperature was 35 ℃,and the injec-tion volume was 10 μl. RESULTS:The linear range was 0.041 0-1.228 8 μg for chlorogenic acid(r=0.999 8)and 0.264 0-7.920 0μg for vitexin(r=0.999 9);RSDs of precision, stability and reproducibility tests were lower than 2%;recoveries were 97.6%-102.3%(RSD=1.85%,n=9) and 97.1%-101.3%(RSD=1.19%,n=9),respectively. CONCLUSIONS:The method is simple,stable and reproducible,and can be used for the simultaneous determination of chlorogenic acid and vitexin in L. gracile.

SELECTION OF CITATIONS
SEARCH DETAIL